Design & Protection |
|
Modules |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ANSI/IEEE & IEC Standards
Transient Fault Analysis (IEC 61363)
Integrates with Arc Flash (NFPA 70E-2000)
Integrates with Device Coordination
Automatic Device Evaluation
|
|
|
|
|
|
|
|
|

Short-Circuit Analysis |
We take the guess-work out of short-circuit
studies. Its as easy as one, two, threeEWe automatically apply all ANSI or IEC factors and ratios, compare
calculated duties to manufacturer published data, and provide alarms and warnings for overstressed devices.
OTI closely monitors industry standards to ensure ETAP is always up-to-date. The Short-Circuit module seamlessly
integrates with device coordination and Arc Flash Hazard calculations. |
| |
|
|
Capabilities
- Check making & breaking capabilities
- Check closing-latching & interrupting capabilities
- Automatic 2,3,5, & 8 cycle breaker comparisons
- User-specified contact parting time
- Breaking duty as a function of breaker time delay
- Interrupting duty as a function of breaker contact parting time
- Automatically includes No AC Decay (NACD) ratio
- Generator circuit breaker duty calculation & rating
- Ith calculation & rating check (IEC)
- Cable temperature adjustment
- User-selected bus faulting (graphical or tabular)
- Grounding models for motors, generators, & transformers
- Motor contribution based upon loading categories
- Fault impedance for line-to-ground faults (ANSI & IEC)
- Option to report breaking duty vs. delay time (IEC)
- Phase-shifting transformers for ANSI unbalanced faults
|
 |
|
|
|
Flexible Operation
- 3 Phase,L-G, L-L, & L-L-G
- Extract manufacturer published data from the libraries (1000s of devices
- Compares device ratings with calculated short-circuit values
- Automatically includes all necessary multiplying factors & ratios
- Automatically adjusts device capabilities based on the nominal & prefault voltages
|
| |
|
|
- IEEE: C37, 141, 242, 399
- UL 489-9
|
|
- 56, 60282-1, 61363, 60781, 60909, 60947
|
| |
|
|
|
Reporting
- Automatically flag marginal & overstressed devices
- Fault current contributions (lsym, la, & 31ø)
- Voltage profiles (Va, Vb, & Vc)
- User-defined fault current contribution level
- Input data, detailed contributions, & summaries
- Phase & sequence currents, voltages, & impedances
- State-of-the-art graphic display of results
- Export output reports to your favorite word processor
- Use Crystal Reports for full color, customizable reports
- Alert view to display critical & marginal limit violations
- Export one-lines with results to third party CAD systems
|
|
|
|
|
Study Options
- Option to update initial conditions
- Phase-shifting transformers
- Auto-adjust LTC/regulator settings
- Power factor correction
- Saves solution control parameters for each scenario
- Make changes to your system & re-run studies
instantly
- Conduct unlimited “what if” studies
within one database
- Calculate bus voltages, currents, & power
factors
- Bus/transformer/cable reactor overload warnings
- Calculate power flows
- Update loading for DC load flow
- Voltage drop calculations
- Five levels of automatic error checking
|
| |
|
|
|
|
 |
 |